Caprisil C18-X/C8-X/C8-X(2) /Caprisil-HILIC-X
The high chemical stability and hydrophobicity of the organic / inorganic hybridunit have a great improvement in resisting hydrolytic corrosion at high pH. Thehybrid particle technology can provide excellent peak shape and columnefficiency, especially for basic compounds.At the same time, the stability of thechromatographic packing in the extreme mobile phase was improved, especiallythe resistance of the packing to the high pH mobile phase was greatly improved.Caprisil C18-X/C8-X /C8-X(2) provides exceptional peak shape and selectivityover a wide pH range (pH 1-12).Caprisil hilic-X provides pH range (pH 2-8).
C18-X |
C8-X |
C8-X(2) |
HILIC-X |
|
Surface Area |
200 m²/g |
200 m²/g |
200 m²/g |
200 m²/g |
Pore Size |
120 Å |
120 Å |
120 Å |
120 Å |
End-capping |
Yes |
Yes |
Yes |
Yes |
Carbon Loading |
18% |
14% |
13% |
- |
USP Code |
L1 |
L7 |
L7 |
L13 |
pH Range |
1-12 |
1-12 |
1-12 |
2-8 |

organic/inorganic hybrid silicagel particles, triple bondtechnology, wide pH range.stable and durable.A variety of bonded phasesmeet the broadest applicability
Column: Caprisil C18-X 250x4.6mm, 5umMobile phase: Methanol: water: trifluoroacetic =5: 95: 0.1 (ph = 2.00)
Flow rate: 0.7 ml/min
Detector: UV 215nm
Injection volume: 10ul
Sample: 1.1-Ethyl-3-(3-dimethylaminopropyl)carbodiimide
Column: Caprisil C18-X250x4.6mm, 5um
Mobile phase: acetonitrile/water(45/55)
Flow rate: 1 ml/min
Column temperature: 30 °C
Detector: UV 245nm
Injection volume: 5ul
Sample: 1.Emamectin
Column: Caprisil C18-X 250x4.6mm, 5um
Mobile phase: Monopotassium phosphate solution (take 13.6 gpotassium dihydrogen phosphate and 1L waer,mix well, measure the PH, keep the PH of theMonopotassium phosphate solution to 4.6)-acetonitrile (49:51)
Flow rate: 1 ml/min
Column temperature: 25 °C
Detector: UV 228nm
Injection volume: 20ul
Sample:1.1.m-nitrobenzaldehyde 2. Impurity VI 3. Impurity I4. lmpurity 5.lmpurity I 6. Manidipine hydrochloride7. lmpurityIv 8.lmpurityv 9. impurity .
Column: Caprisil C8-X 250x4.6mm, 5um
Mobile phase: 0.01mol/L disodium hydrogen phosphatesolution (adjust PH to 7.6 with phosphoric acid)acetonitrile (75:25)
Flow rate:1 ml/min
Column temperature: 30 °C
Detector: UV 302nm
Injection volume: 20ul
Sample: 1. Omeprazole
Column: Caprisil-HILlC-X
Mobile phase: N-hexane-N-pentanol = 995:5
Flow rate: 1.5 ml/min
Detector: UV 265nm
Injection volume: 20u
Part Number |
Long Description |
CA533-C18-TH |
Caprisil C18-TH 3μm 100Å 50mm×4.6mm |
CB533-C18-TH |
Caprisil C18-TH 3μm 100Å 100mm×4.6mm |
CC533-C18-TH |
Caprisil C18-TH 3μm 100Å 150mm×4.6mm |
CA553-C18-TH |
Caprisil C18-TH 5μm 100Å 50mm×4.6mm |
CB553-C18-TH |
Caprisil C18-TH 5μm 100Å 100mm×4.6mm |
CC553-C18-TH |
Caprisil C18-TH 5μm 100Å 150mm×4.6mm |
CD553-C18-TH |
Caprisil C18-TH 5μm 100Å 200mm×4.6mm |
CE553-C18-TH |
Caprisil C18-TH 5μm 100Å 250mm×4.6mm |
Note : we can able to providecustamized columns.

We have individual Technical and R & D Team and worked more than 60 + Experienced Analytical Scientists. we are ready to support Technically before and after sales. For New analytical Method Development or validation, we can able to help to find right columns. our R & D Team can able to provide Customized columns. for more technical information’s kindly contact us. morhchem@technicalsuppport.com